Inovance MD500 Inverter

The Inovance MD500 is a compact, high-performance AC inverter designed for precise motor control and energy efficiency in industrial automation.
Ideal for packaging, printing, and HVAC, it offers fast response, strong protection, and flexible communication.

  • Compact design for easy cabinet installation
  • Fast response for accurate torque and speed control
  • Full protection against overvoltage, overcurrent, and overheating
  • Flexible control with V/F, Vector, and PM motor modes
  • Built-in Modbus RTU / EtherNet/IP communication

Delivering reliability and performance, the MD500 ensures stable operation and reduced downtime across diverse automation systems.

inovance

🧠 How the Inovance MD500 Reports Errors

When a fault occurs, the drive automatically stops output to protect the motor and displays an “ErrXX” code on its keypad. The TUNE/TC LED flashes, and a trip log is saved.

TypeDescriptionLED BehaviorRecovery
Fault (Err)Stops drive output immediately.LED flashesMust be manually reset.
Warning (AL)Alerts of an issue; continues running.LED steadyCorrect parameter or cooling.
Protection StopStops output; self-resets after condition clears.—Auto reset when safe.

📘 Tip: Access F9-14 to F9-44 to view the last three fault logs (including voltage, current, and status at the time of failure).

🔁 How to Reset Faults

MethodActionUse Case
Panel ResetPress STOP/RES if F7-02 = 1.Normal reset after fix.
DI Terminal ResetAssign DI terminal function = 9 (Fault Reset).Remote reset from PLC.
Power CycleTurn OFF then ON.Clears latched faults.
Communication ResetSet F0-02 = 2, write “7” to address 2000H.Remote monitoring systems.

🧾 Inovance MD500 Error Codes and Solutions

Below is the comprehensive list of Inovance MD500 error codes (Err01–Err62), organized with fault names, causes, and corrective actions — extracted from the official manual and restructured for field use.

Error CodeFault NamePossible CausesSolutions
Err02Overcurrent during accelerationGround fault, short circuit, no auto-tuning, accel too short, wrong current limit, external interference.Check motor wiring; perform auto-tuning; increase accel time; enable current limit (F3-19 = 1); adjust F3-18 (120–150%), F3-20 (20–40).
Err03Overcurrent during decelerationShort circuit, no auto-tuning, decel too short, missing brake resistor, interference.Check cables; perform auto-tuning; install braking resistor; extend decel time.
Err04Overcurrent at constant speedGround fault, improper torque boost, undersized drive, interference.Inspect motor leads; reduce F3-01 torque boost; upgrade drive class.
Err05Overvoltage during accelerationInput voltage high, short accel time, regenerative energy.Normalize supply; enable voltage limit (F3-23 = 1); install brake resistor; increase accel time.
Err06Overvoltage during decelerationShort decel, external force, missing resistor.Enable voltage limit; increase decel time; install braking resistor.
Err07Overvoltage at constant speedExternal load feedback energy.Install braking resistor; tune F3-22 (700–770 V); adjust F3-24 (30–50).
Err08Pre-charge resistor faultBus voltage fluctuation.Contact Inovance or agent.
Err09UndervoltagePower dip, supply out of range, rectifier fault.Enable ride-through (F9-59 ≠ 0); stabilize input power; replace rectifier if faulty.
Err10Drive overloadHeavy load or locked rotor.Reduce mechanical load; use larger-rated drive.
Err11Motor overloadWrong F9-01 setting or excessive torque.Set F9-01 correctly; reduce load.
Err12Input phase lossMissing phase or rectifier damage.Inspect input R/S/T; check fuses; replace rectifier if needed.
Err13Output phase lossBroken motor winding, bad cable, or IGBT fault.Check continuity; replace motor or drive board if unbalanced.
Err14IGBT overheatHigh temperature, blocked fan, sensor failure.Clean vents; replace fan or sensor; reduce ambient temperature.
Err15External faultDI input or virtual I/O triggered.Reset after clearing input (F8-18/A1 settings).
Err16Communication faultWrong protocol, cable noise, Modbus setting mismatch.Verify F0-28, Fd-group; check cable shielding.
Err17Contactor faultRelay or lightning board failure.Replace defective boards or contactor.
Err18Current detection faultHall sensor failure.Replace hall sensor or drive board.
Err19Auto-tuning faultWrong motor data, encoder issue.Enter correct motor parameters; verify encoder wiring.
Err20Encoder faultWrong type, damaged encoder, wiring error.Correct encoder setting (F1-27); check PG card; replace encoder.
Err21EEPROM faultMemory failure.Replace main control board.
Err23Ground short circuitMotor insulation failure.Replace cable or motor; perform megger test.
Err26Running time limit reachedRuntime limit triggered.Reset via parameter initialization.
Err27 / Err28User-defined faultsDI/virtual I/O triggered.Reset; verify user logic settings.
Err29Power-on time exceededAccumulated time limit reached.Reset runtime counter.
Err30Load lossOutput current < F9-64.Reconnect load; adjust F9-64/F9-65.
Err31PID feedback lostFeedback signal below FA-26.Check PID sensor; correct FA-26 threshold.
Err40Pulse-by-pulse current limitHeavy load or undersized drive.Reduce torque; use higher-rated drive.
Err41Motor switchover faultSwitched motor during run.Switch only when stopped.
Err42Speed errorEncoder data mismatch, no auto-tuning.Perform auto-tuning; check F9-69/F9-70 values.
Err43OverspeedEncoder/parameter mismatch.Perform auto-tuning; adjust F9-67/F9-68.
Err45Motor overtemperatureHigh temperature or loose sensor wiring.Tighten connections; improve cooling; reduce carrier frequency.
Err51Braking unit overloadResistor too small or frequent decel.Replace with larger resistor; extend decel time.
Err62Braking circuit shortBraking IGBT damaged.Replace IGBT; contact Inovance.

🧮 Parameter Groups to Check

Parameter GroupFunctionNotes
F3-xxVoltage and current limitAdjust F3-18, F3-22, F3-24 for stall and voltage protection.
F8-xxDI/DO logic setupCheck F8-18 for restart permissions.
F9-xxProtection and monitoringF9-59 = ride-through; F9-64–F9-70 = load and speed error detection.
FA-xxPID control parametersAdjust FA-26 for feedback level detection.

⚠️ Safety Reminder: Before inspection or resetting, disconnect power for at least 10 minutes to allow DC bus capacitors to discharge.

🧰 Quick Troubleshooting Flow

  1. Read code on display (e.g., “Err06”).
  2. Check fault log (F9-14 – F9-44).
  3. Verify motor and wiring for shorts, phase loss, or overheating.
  4. Confirm parameters (F3, F8, F9) are within safe ranges.
  5. Fix mechanical causes (load, fan, environment).
  6. Reset drive via keypad or DI input.
  7. Run test to confirm stability.

🔧 Preventive Maintenance

  • Inspect fans, vents, and heatsinks quarterly.
  • Use shielded cables and grounded wiring to minimize EMI.
  • Perform motor auto-tuning after replacement or rewiring.
  • Back up parameters before firmware or hardware changes.
  • Monitor F9-05 (DC bus voltage) and U4-xx (lifetime counters) regularly.

✅ Summary

The Inovance MD500 error codes system provides a structured, intelligent diagnostic method to keep your VFDs healthy.
From simple faults like Err02 (Overcurrent) to complex control issues like Err20 (Encoder fault), each code reflects a specific hardware or operational problem — and offers clear guidance for resolution.

By learning these codes and keeping your parameters optimized, you can dramatically reduce unplanned downtime and extend the life of your Inovance MD500 drive.