A thermal paper roll manufacturer receives a complaint from a customer.
The customer ordered thermal receipt rolls with a specified paper length, but after measuring several samples, they found that the actual length did not match the quantity stated on the packaging.

The production operator checks the slitter rewinder. The touchscreen shows the correct target length, and the machine appears to be completing each winding cycle normally.
So where did the missing metres go?
Incorrect thermal paper roll length is not always caused by the operator entering the wrong setting. The problem may originate from the measuring wheel, encoder, PLC counting configuration, mechanical contact conditions, or the way the winding cycle is completed.
For manufacturers producing POS receipt rolls, ATM paper rolls, and other thermal paper products, length accuracy is important because the customer expects to receive the quantity of paper specified in the order.
A roll may have the correct width and outside diameter while containing a different length of paper than expected.
At JOTA Machinery, length measurement and control are considered during the electrical design, programming, and commissioning of our thermal paper slitting and rewinding machines.
Our in-house programmers review the technical manuals of the relevant electrical components and configure the control system according to their operating requirements.
But understanding the control system is only part of the job. Actual material measurements are also necessary to verify that the finished rolls meet the specified length.
This article explains how a measuring wheel and encoder work, why length errors occur, and how thermal paper converters can investigate and prevent them.
1. Why Does Thermal Paper Roll Length Matter?
Thermal receipt rolls are commonly specified by paper width, outside diameter, core dimensions, and sometimes the paper length in metres.
These dimensions are related, but they do not describe the same property.
Consider two finished thermal paper rolls with the same outside diameter.
If one is made from thicker paper and the other from thinner paper, their actual paper lengths may differ.
Core geometry and winding conditions can also affect the relationship between diameter and length.
Therefore, a machine cannot reliably determine the exact length of paper simply by measuring the finished roll diameter.
For orders requiring a specified number of metres, a length-measurement system is needed.
What Happens When the Length Is Incorrect?
If a manufacturer specifies 50 metres per roll but delivers a smaller quantity, the customer receives less paper than expected.
This may result in complaints, rejected stock, or disagreements about the product specification.
If the rolls are consistently longer than required, the manufacturer may consume more raw material than planned.
Even a relatively small systematic error can become commercially significant when thousands of rolls are produced.
The objective is to keep the actual finished length within an agreed tolerance, using a measurement and control system that performs consistently throughout production.
2. How Does a Measuring Wheel Work on a Slitter Rewinder?
A common method of measuring moving web material involves a measuring wheel and rotary encoder.
The measuring wheel contacts the moving paper.

As the paper travels through the machine, friction between the surfaces causes the wheel to rotate.
An encoder connected to the measuring wheel converts this rotation into electrical signals.
The control system processes the signals to calculate the length of paper that has travelled through the measuring point.
The basic principle is straightforward.
If the measuring wheel has a circumference of 200 mm, one complete rotation represents 200 mm of paper travel, assuming the wheel rolls without slipping.
Five complete rotations would therefore represent approximately one metre of paper movement.
The encoder makes it possible to measure fractions of a revolution rather than counting complete rotations manually.
Why Use a Rotary Encoder?
A rotary encoder produces signals corresponding to shaft rotation.
An incremental encoder, for example, generates pulses as its shaft rotates.
The PLC or other controller counts these signals and converts them into a calculated length.
The relationship depends on the encoder resolution and the counting configuration.

Some controllers count a defined number of pulses per revolution.
Others may use quadrature decoding, where multiple signal transitions are counted for each encoder pulse cycle.
The programmer must use the correct counting method when calculating the length.
Otherwise, the displayed value may differ substantially from the actual paper travel.
3. How the PLC Calculates Paper Length
The basic length calculation is based on the measuring wheel circumference and the number of encoder counts corresponding to one revolution.
Measured Length = (Encoder Counts ÷ Counts per Revolution) × Effective Wheel Circumference
This formula assumes that the measuring wheel rotates in accordance with the movement of the paper and that the effective wheel circumference has been correctly established.
A Simple Calculation Example
Suppose a hypothetical measuring system has the following characteristics:
| Parameter | Example Value |
|---|---|
| Effective wheel circumference | 200 mm |
| Encoder counts per revolution | 1,000 |
| Recorded encoder counts | 250,000 |
The calculated paper length is:
250,000 ÷ 1,000 × 200 mm = 50,000 mm
That equals:
50 metres
In this example, the controller would display 50 metres of measured paper travel.
However, this is only a mathematical illustration. It is not a technical specification for a JOTA machine.
The calculated result is accurate only when the encoder signals, counting configuration, wheel calibration, and mechanical contact conditions are correct.
Why the Effective Circumference Matters
The theoretical circumference of a circular measuring wheel is:
Circumference = π × Diameter
But the effective rolling circumference can differ from the nominal geometric value because of wheel construction, loading, wear, and contact conditions.
For precision length measurement, the appropriate conversion factor should be established and verified on the installed machine.
Entering a nominal wheel diameter into the PLC without checking the actual measurement can introduce systematic error.
4. Measuring Wheel Slippage: A Common Source of Length Error
One important cause of inaccurate thermal paper roll length is slippage between the measuring wheel and the moving paper.
The wheel measures material movement indirectly.
It assumes that the wheel surface moves together with the paper without slipping.
If this relationship is disturbed, the encoder may report less or more movement than the material actually travels, depending on the type of slip and measurement arrangement.
What Happens When the Wheel Slips?
Consider a passive measuring wheel driven by contact with the moving paper.
If the paper travels forward but the wheel rotates less than it should, the encoder registers fewer counts.
As a result, the PLC may underestimate the paper length.
If the machine uses that underestimated measurement to decide when the roll is complete, the final roll can contain more paper than the target length.
This is an important distinction: measuring wheel slippage does not always result in a short roll.
The direction of the error depends on how the measurement signal and winding control are used.
What Can Cause Slippage?
Possible causes include insufficient wheel contact force, an unsuitable wheel surface, contamination, vibration, or unstable web movement.
The wheel may also behave differently when the machine accelerates or decelerates.
How to Check for Slippage
Inspect the measuring wheel and its contact arrangement according to the machine’s maintenance instructions.
Check that the wheel surface is clean and in suitable condition.
Verify the specified contact force or loading arrangement, where applicable.
Do not increase pressure without considering the paper surface and wheel design.
Excessive contact force can introduce other problems, including unwanted marks or mechanical wear.
A practical diagnostic method is to compare the displayed length with a separately measured reference length.
If the error varies with speed or operating conditions, examine whether wheel contact stability is contributing to the problem.
5. Incorrect Measuring Wheel Circumference
Another possible cause is an incorrect wheel circumference setting in the controller.
The PLC uses a conversion factor to translate encoder counts into linear length.
If that factor is wrong, the calculated length will also be wrong.
Example of a Calibration Error
Suppose the controller is configured using an effective circumference of 200 mm.
However, the actual effective rolling circumference is 199 mm.
Even if the encoder counts every rotation correctly, the controller will calculate more paper movement per revolution than actually occurred.
The displayed length will therefore be higher than the true length.
If the machine stops at a displayed target of 50 metres, the actual paper length may be shorter than 50 metres.
The difference can accumulate over a long production run.
Why Wheel Wear Matters
The effective wheel circumference may change over time.
Depending on its material and construction, the wheel surface may wear or experience changes in its contact characteristics.
Contamination can also affect measurement behaviour.
For this reason, a length-measurement system should not be assumed to remain perfectly calibrated indefinitely.
Where required, the wheel condition and measurement accuracy should be checked during routine maintenance.
6. Encoder Resolution and PLC Counting Configuration
The encoder and controller must be configured to work together.
A rotary encoder may specify its resolution in pulses per revolution, commonly abbreviated as PPR.
However, the controller may use a counting method that produces a different number of counts per revolution.
For example, a quadrature encoder may provide two signal channels.
Depending on the controller configuration, the program may count one, two, or four signal transitions per encoder cycle.
The resulting counts-per-revolution value must match the calculation used in the control software.
What Happens When the Configuration Is Incorrect?
If the PLC uses the wrong counting factor, the measured length can differ significantly from actual paper movement.
The machine may still appear to operate normally.
The touchscreen can display a stable number, but that number may be based on an incorrect conversion.
This illustrates why programming accuracy depends on understanding the electrical components, not simply writing code that increments a counter.
Why Electrical Manuals Matter
Encoder manufacturers provide technical manuals describing output signals, resolution, wiring, power requirements, and permitted operating conditions.
The PLC and high-speed counting modules also have their own specifications.
The electrical engineer must verify that these components are compatible and correctly configured.
For example, the input frequency generated at the machine’s maximum operating speed must remain within the counter’s supported range.
Incorrect wiring, signal handling, or filtering may result in missing or false counts.
Increasing encoder resolution alone does not correct mechanical slippage or an incorrect scaling factor.
7. Why Correct PLC Programming Is Important
A length-measurement system involves more than the encoder and measuring wheel.
The PLC must interpret the incoming signals and use them correctly within the production sequence.
Depending on the slitter rewinder design, the control program may need to manage measuring, acceleration, deceleration, winding completion, cutting, and the next production cycle.
The Measuring Function
The program converts encoder counts into length using the correct calibration and counting parameters.
The Winding Sequence
The controller must identify when a new roll begins and when its target length has been reached.
The counting logic must correspond to the actual material movement during the production cycle.
Counter Reset and Data Handling
If the machine resets its counter at the wrong point or omits a portion of material movement, the displayed length can differ from the material wound into the finished roll.
Motion and Stopping Behaviour
Depending on the machine design, some paper may continue moving after a deceleration or stop command is issued.
The program must account for this behaviour where it affects the finished roll length.
The required logic depends on the actual mechanism.
A generic software calculation cannot be copied blindly between machines with different electrical components and winding sequences.
How JOTA Approaches Control Programming
At JOTA Machinery, our in-house programming personnel review the technical documentation supplied with the electrical components used in our machines.
This includes understanding the encoder signal characteristics, controller inputs, relevant operating parameters, and the logic required for the machine’s actual production cycle.
The purpose is to establish a stable control program in which material measurement and machine operation are correctly coordinated.
During commissioning, the displayed length must also be compared against an independent physical measurement.
Careful programming helps reduce avoidable measurement errors, but accurate finished rolls ultimately need to be verified by testing.
8. The Machine Reaches the Target Length but the Finished Roll Is Still Wrong
Sometimes the measuring wheel and encoder appear to be functioning correctly.
The machine displays the expected target length.
But the finished paper roll still does not contain the specified amount of paper.
This can happen when the counted length does not correspond exactly to the paper included in the finished product.
Material Movement During Stopping
On some machine designs, the paper continues travelling while the drive decelerates.
If the measurement logic stops counting too early, or if the machine’s completion sequence does not account for the additional movement, the final length may be affected.
Conversely, an incorrect completion offset can cause the machine to finish before the intended length has been wound.
Counting During the Wrong Production Stage
The position of the measuring point matters.
A sensor measures paper movement at its installed location.
However, the finished roll length is determined by the amount of paper actually wound into the completed product.
Depending on the web path and machine sequence, these two quantities may not be identical at every moment.
This is particularly relevant when a machine includes temporary web storage, automatic roll changing, or other coordinated mechanisms.
The control program must be designed around the specific mechanical arrangement.
Why Running Speed Can Influence the Error
If the length difference changes significantly with production speed, investigate how the control system behaves during acceleration, deceleration, and cycle completion.
A consistent percentage error may suggest a scaling or wheel-calibration issue.
An error that changes with operating conditions may indicate a different problem.
These patterns are useful clues, but they should be confirmed through testing before changing program parameters.
9. How to Check Whether the Thermal Paper Roll Length Is Accurate
A displayed length on the machine is not sufficient proof of finished roll accuracy.
The most direct method is to compare the specified length with an independent measurement of the finished material.
Step 1: Prepare a Test Specification
Select a representative finished thermal paper roll specification.
Record the paper grade, target length, machine settings, and operating conditions.
Step 2: Produce Test Rolls
Run the machine using its normal approved operating sequence.
Produce multiple samples under the same conditions.
This helps determine whether the length error is consistent or varies between rolls.
Step 3: Measure the Actual Paper Length
Use an appropriate independently verified measuring method to determine the finished paper length.
The measurement process should avoid excessive tension or stretching that could affect the result.
Do not treat the machine’s own displayed value as an independent reference.
Step 4: Calculate the Length Difference
The basic calculation is:
Length Error = Actual Measured Length − Target Length
For a percentage comparison:
Length Error (%) = [(Actual Length − Target Length) ÷ Target Length] × 100
A positive result means the finished roll is longer than the target.
A negative result means it is shorter.
Step 5: Compare Several Samples
Check whether all rolls show a similar error.
If the difference is consistent, investigate measuring-wheel calibration and the PLC conversion factor.
If the results vary significantly between rolls, examine mechanical contact, counting stability, and machine operating conditions.
Step 6: Test Under Representative Production Conditions
A machine may perform well during a short, low-speed trial but behave differently at the intended production speed.
Length verification should therefore include realistic operating conditions and production cycles.
Step 7: Record the Results
Document the target length, actual measured length, calculated error, test conditions, and any corrective action.
These records provide evidence that the length-control system has been checked against the finished product.
10. A Practical Troubleshooting Table
| Observed Problem | Possible Cause | Recommended Check |
|---|---|---|
| All rolls are consistently too short | Incorrect scaling, excessive calculated length, completion offset | Check effective circumference, counting factor, control sequence |
| All rolls are consistently too long | Measuring-wheel undercounting, calibration, completion timing | Check wheel contact, encoder counts, actual stopping sequence |
| Length difference changes between rolls | Unstable wheel contact, pulse counting, cycle inconsistency | Inspect wheel mechanism and measurement signals |
| Error increases with production speed | Slip, signal limitations, motion control response | Compare tests at approved speeds |
| Displayed length appears correct but actual length differs | Calibration or logic error | Verify with independent measurement |
| Error begins after replacing the measuring wheel | Different effective circumference | Recalibrate installed measuring system |
| Error begins after electrical maintenance | Changed parameters, wiring, counting configuration | Review original component manuals and control settings |
| Errors appear around roll changes | Cycle timing or counter reset logic | Check production sequence and measurement intervals |
Operators should not attempt to correct an unexplained error by repeatedly changing the displayed target length.
That may temporarily compensate for a particular condition without addressing the underlying measurement problem.
The correct approach is to identify whether the error originates from mechanical measurement, electrical signal processing, or production control logic.
11. Why In-House Programming Matters for Machine Manufacturers
A slitter rewinder contains electrical and mechanical components that must operate as one coordinated system.
The measuring wheel, encoder, PLC, drives, and winding mechanism each perform different functions.
Correct length control depends on how those functions interact.
Using a suitable encoder is important.
But the encoder’s performance also depends on correct installation, signal processing, parameter configuration, and calibration.
A carefully written control program should reflect the actual component specifications and machine operating sequence.
Reading the Component Manuals Before Programming
At JOTA Machinery, our own programming personnel review the electrical component documentation as part of developing the control system.

For the length-measurement function, this includes checking the encoder specifications and the PLC’s relevant counting and processing requirements.
The programmer must understand what the signals represent before converting them into the length displayed on the operator interface.
The same principle applies to the associated drive and machine-cycle controls.
Testing the Program on the Machine
Correct calculations do not automatically guarantee correct finished products.
After programming, the system must be checked under real operating conditions.
The displayed length should be compared with the actual measured paper length.
If the difference exceeds the agreed tolerance, the cause must be investigated and corrected.
Our engineering objective is to keep the difference between the specified length and the actual finished roll length as small and consistent as practicable.
The achievable accuracy depends on the machine configuration, material, measuring arrangement, and agreed acceptance conditions.
Accurate roll length is the result of component selection, careful programming, calibration, and physical verification—not software alone.
12. What Should Buyers Verify During Factory Acceptance Testing?
When purchasing a thermal paper slitting and rewinding machine, buyers should include finished roll length verification in the Factory Acceptance Test (FAT).
It is not enough to enter a target length on the touchscreen and observe that the machine stops automatically.
The buyer should verify the actual length of the finished rolls.
Recommended FAT Checks
Target Length: Enter an agreed length through the machine’s normal operating interface.
Finished Roll Measurement: Independently measure the actual length of representative completed rolls.
Repeatability: Produce multiple samples to assess consistency.
Production Speed: Test at agreed representative running conditions.
Length-Control Sequence: Verify that the measurement and completion functions operate properly during normal winding cycles.
Documentation: Record the target and measured results, deviations, and relevant operating conditions.
The acceptance tolerance should be agreed before testing.
Different machine configurations and products may require different limits, so an unverified universal tolerance should not be promised.
This process gives the customer a more meaningful understanding of the machine’s actual length-control performance.
Conclusion: Accurate Length Requires More Than a Meter Counter
When the actual length of thermal paper rolls does not match the specified quantity, the problem may originate from several parts of the measuring and control system.
Measuring-wheel slippage, incorrect effective circumference, encoder counting configuration, PLC scaling, and winding-cycle logic can all contribute to length errors.
The meter counter is an important component, but it does not work independently of the machine.
Its signals must be correctly interpreted, and the control program must reflect the actual mechanical production sequence.
At JOTA Machinery, our in-house programmers study the relevant electrical component manuals and develop the control logic for the selected machine configuration.
This attention to component specifications helps us reduce avoidable measurement errors and maintain stable machine operation.
Most importantly, the result must be confirmed by measuring actual finished thermal paper rolls.
A reliable length-control system should not simply display the expected number of metres.
It should produce finished rolls whose independently measured length meets the agreed production specification.
Looking for a Thermal Paper Slitting Rewinding Machine With Reliable Length Control?
JOTA Machinery manufactures thermal paper slitting and rewinding equipment for POS receipt rolls, thermal till rolls, ATM paper rolls, and other converting applications.
If your production requires specified paper lengths, share your jumbo paper dimensions, finished roll specifications, target metres per roll, and required length tolerance.
Our engineering team can discuss the appropriate measuring and control arrangement and the length-verification tests needed during commissioning.
Discuss Your Thermal Paper Roll Production Requirements
Last Updated on 21/10/2026 by Jota Machinery