A slitter rewinder is running, but the operator notices something unusual.
The tension display shows a stable value, yet the paper web continues to wrinkle or become loose during production.
The operator adjusts the tension setting, but the problem remains.
Could the web tension sensor be giving an incorrect reading?
In roll-to-roll converting equipment, accurate tension measurement is essential for controlling how paper, plastic film, labelstock, and other flexible materials travel through the machine.
If a tension sensor has an incorrect zero point or calibration factor, the displayed tension may differ from the actual force acting on the web.
This can affect troubleshooting and, on machines using closed-loop tension control, the way the controller regulates the unwinding or rewinding system.
One practical method of checking and calibrating web tension sensors is deadweight calibration, also known as calibration using standard test weights.

The method uses a known mass to apply a reference force through the measuring system.
For a typical slitter rewinder equipped with a load-cell measuring roller, a cord or suitable non-elastic strap is routed through the normal web path, and a known weight is suspended from one end.
The sensor output is then checked or adjusted according to the tension controller’s calibration procedure.
However, the accuracy of this method depends on more than the weight itself.
The web path, roller wrap angle, sensor mounting direction, zero setting, and controller configuration all affect the result.
This article explains how to calibrate a web tension sensor using test weights, what to prepare before calibration, and how to identify common errors during the process.
1. What Is a Web Tension Sensor?
A web tension sensor is a measuring device used to detect forces associated with a moving material web.
In slitting and rewinding equipment, tension sensors are commonly installed on the supports of a measuring roller.
As the paper or film passes around the roller, the tension in the material creates a resultant force acting on the roller.
The supporting load cells detect the force transmitted through the roller bearings or mounting structure.
Their electrical signals are processed by an amplifier, tension indicator, PLC, or other control system.
The system then calculates or displays the corresponding web tension.
Why Does a Slitter Rewinder Need Tension Measurement?
Web tension influences how the material travels through the production line.
If the actual tension becomes too low, the web may develop slack or wrinkles.
If the tension becomes excessive, the material may stretch, tear, or experience other problems.
The appropriate tension depends on the substrate, web width, roll diameter, machine arrangement, and converting operation.
A correctly configured measurement system helps operators monitor these conditions.
Is a Tension Sensor the Same as a Load Cell?
The terms are often used together.
A load cell is a force-measuring component.
A web tension sensor assembly may include one or more load cells and the mechanical components needed to measure forces from a moving web.
The complete web tension measurement system also includes signal processing and, where applicable, geometric compensation.
This distinction matters during calibration.
A calibration method suitable for a standalone tensile load cell is not necessarily identical to the method required for an installed web tension measuring roller.
2. Why Should Web Tension Sensors Be Calibrated?
A tension sensor may produce an electrical signal without displaying the correct web tension.
Several conditions can influence the measurement.
Incorrect Zero Point
The measuring roller has its own weight.
Depending on the sensor installation, that weight can contribute to the load-cell signal.
If the controller does not compensate correctly, the system may show a tension value even when no web tension is present.
Incorrect Calibration Factor
The controller converts the sensor signal into a displayed tension value.
If the conversion factor is incorrect, the system may consistently overestimate or underestimate the actual tension.
Mechanical Changes
Replacing the measuring roller, changing its mounting arrangement, or modifying the web path can change the mechanical forces detected by the sensors.
A new calibration or verification may be needed.
Sensor Replacement
A replacement load cell may have different sensitivity or electrical characteristics.
The controller should be configured according to the replacement sensor’s specifications.
Measurement Drift or Unstable Readings
Electrical faults, wiring damage, poor connections, temperature effects, or mechanical binding may cause measurement problems.
Calibration can identify some errors, but it cannot repair a damaged sensor or defective installation.
The purpose of calibration is to establish a reliable relationship between a known reference force and the measurement system’s output.
3. How Does Deadweight Calibration Work?
Deadweight calibration uses a known mass to generate a reference gravitational force.

The basic principle is:
Force (N) = Mass (kg) × Local Gravitational Acceleration (m/s²)
For ordinary industrial calculations, gravitational acceleration is often approximated as 9.81 m/s².
For example, a 5 kg test mass produces a gravitational force of approximately 49.05 N under this approximation.
The force can be used as a reference during calibration.
However, a web tension measuring roller does not simply measure the downward force of the suspended weight.
It measures the resultant force produced by the tension in the cord or web passing around the roller.
That resultant force depends on the geometry of the material path.
Why the Web Path Matters
Imagine a paper web travelling over a measuring roller.
The web approaches the roller from one direction and leaves in another direction.
The tensions acting along the two web spans combine to create a resultant force on the roller.
Changing the wrap angle changes that resultant force.
Therefore, a calibrated weight must be applied through the correct mechanical geometry.
This is why manufacturers commonly recommend routing the calibration cord along the same path as the production web.
4. What Equipment Is Needed for Weight Calibration?
Before beginning, prepare the equipment required by the sensor and controller manufacturer’s instructions.
| Equipment | Purpose |
|---|---|
| Known test weight | Provides a reference loading force |
| Suitable non-elastic cord or strap | Transmits the reference tension through the roller path |
| Tension display or control interface | Shows the measured or calculated tension |
| Approved mounting or anchoring point | Secures the cord during the test |
| Sensor technical documentation | Provides calibration instructions and load limits |
| Calibration record | Documents the settings and results |
| Appropriate safety equipment | Supports safe work around suspended loads |
Select an Appropriate Test Weight
Use a weight with a known mass and suitable traceability.
Where required by the factory’s quality system, the mass should be calibrated and supported by a valid certificate.
Do not assume the nominal marking on an ordinary workshop weight is sufficiently accurate for every calibration requirement.
How Heavy Should the Test Weight Be?
There is no single percentage suitable for all web tension controllers.
For example, BST documentation recommends a calibration mass corresponding to at least 20% of the known maximum web tension for its specified procedure.
Other manufacturers may prescribe a different minimum calibration load.
The correct reference must be selected according to the actual controller manual and the permitted loads on the measuring system.
Never exceed the sensor, roller, mounting, or rigging capacity.
5. Step 1: Inspect the Tension Sensor Installation
Before adjusting the electronic calibration, inspect the mechanical installation.
If the measuring roller or load cell is incorrectly mounted, the system may not provide reliable readings.
Check the Measuring Roller
Verify that the roller rotates freely and is not mechanically obstructed.
Excessive bearing resistance or structural contact can introduce measurement errors.
Check the Load Cell Mounting
Inspect the load-cell supports and mounting fasteners according to the machine manual.
The applied force should act in the intended sensing direction.
Check Sensor Wiring
Inspect relevant connectors and cables for visible damage.
A poor connection can cause intermittent or unstable readings.
Verify the Measuring Direction
Some load cells have a specified measuring axis or force-direction marking.
The controller may also require the mounting orientation to be entered during configuration.
An incorrect orientation can affect how the signal is interpreted.
If the installation is unsuitable, correct the mechanical problem before carrying out calibration.
6. Step 2: Stop the Machine and Prepare the Web Path
Weight calibration should be performed under controlled, non-running conditions unless the manufacturer specifies a different approved procedure.
Stop the converting machine.
Apply the required hazardous-energy isolation and safe maintenance procedures.
Prevent unintended movement of the rollers, drives, unwind stand, and other machinery.
Remove Normal Web Tension
For the zero-adjustment stage, the measuring roller should not experience tension from the production material.
Depending on the installation, the material may need to be removed or completely relaxed.
Determine the Original Paper Path
Before removing material, document the original web route.
Identify the rollers before and after the tension measuring roller.
The calibration cord must reproduce the relevant wrap geometry.
Why You Should Not Change the Wrap Angle
A different wrap angle changes the resultant force acting on the tension measuring roller.
If the calibration cord follows a different route from the production paper, the electronic system may be adjusted using an incorrect mechanical relationship.
As a result, the display could appear correct during calibration but give inaccurate values during normal production.
7. Step 3: Perform the Zero Calibration
The zero calibration establishes the output corresponding to no applied web tension.
The measuring roller itself may still exert weight on the sensors.
The purpose is to compensate for the applicable unloaded assembly condition, not to physically remove the measuring roller’s weight.
Zero-Adjustment Procedure
First, confirm that no production web tension is acting on the measuring roller.
Allow the measuring electronics to reach the operating condition specified by the manufacturer.
Open the tension controller’s calibration menu.
Select the appropriate zero-calibration function.
Wait for the indicated process to complete.
Confirm that the tension display is at or near the intended zero value.
Why Zero Calibration Matters
Suppose the display indicates 8 N when no web tension is present.
If that offset remains uncorrected, it may influence subsequent measurements.
However, a non-zero reading can also indicate a mechanical or electrical problem.
If the value is unstable or outside the manufacturer’s permitted zeroing range, investigate the cause rather than repeatedly resetting the instrument.
Should Both Sensors Be Zeroed Separately?
Some measuring rollers have load cells at both ends.
The calibration procedure may treat the sensors separately or as a combined measurement channel.
Follow the installed amplifier and controller instructions.
Do not assume that every two-load-cell system requires the same electronic zeroing sequence.
8. Step 4: Route the Calibration Cord Around the Measuring Roller
This is one of the most important steps.
Use a suitable non-elastic cord or strap and route it along the same path as the paper web.
Where specified, position the cord at the centre of the measuring roller.
The cord should pass over the relevant freely rotating idler rollers before and after the measuring roller.
One end is secured to an approved anchoring point.
The known test weight is suspended from the other end.
Why Use Idler Rollers?
A freely rotating idler generally introduces less resistance than a driven or braked roller.
If the cord passes over a roller that creates significant friction or resisting torque, the tension may differ between portions of the cord.
The applied reference may then become inaccurate.
Avoid Driven or Braked Rollers
Several calibration manuals specifically warn against routing the calibration cord through driven rollers, braked rollers, or drag bars.
These components can introduce forces that invalidate the assumed reference tension.
Keep the Weight Clear
The suspended test weight must hang freely.
It must not touch the floor, machine frame, or other components.
It should also be prevented from swinging excessively.
The lifting and suspending arrangement must be rated for the load and secured by qualified personnel.
9. Step 5: Apply the Known Weight and Calibrate the Span
After the cord has been correctly installed, apply the prescribed test weight.
The weight creates tension in the cord.
The cord produces a force on the measuring roller according to the wrap geometry.
The load cells convert that force into an electrical signal.
The tension controller then interprets the signal according to its calibration and configuration.
Enter the Reference Value
Some digital controllers allow the operator to enter the known calibration weight directly.
For example, a controller may request a 5.0 kg calibration mass.
Other instruments may request a force value in newtons or another unit.
Always confirm the actual unit shown on the calibration screen.
Do not enter 49.05 into a field expecting 5.0 kg.
Perform the Calibration
With the weight stationary and the reference load stable, follow the controller’s span-calibration procedure.
The instrument may calculate and save a new conversion factor.
Some analogue systems use dedicated calibration adjustments.
The exact procedure varies by manufacturer.
Why the Display May Not Equal the Total Roller Load
The measuring roller receives a resultant force created by the two tensioned cord spans.
A properly configured web tension controller converts that measured force into an equivalent web tension value.
Therefore, the total force acting on the roller may differ from the displayed web tension.
The correct comparison is the one defined by the controller manufacturer’s calibration method.
10. How Does Wrap Angle Affect Calibration Accuracy?
The wrap angle determines the relationship between the tension in the web and the resultant force acting on the measuring roller.
For an idealised system with equal incoming and outgoing tensions:
Resultant Force = 2 × Web Tension × sin(Wrap Angle ÷ 2)
This formula describes the magnitude of the resultant force before considering how that force is distributed between sensors and projected onto their sensing axes.
Example: A 90-Degree Wrap Angle
Suppose the web tension is 50 N and the wrap angle is 90 degrees.
The resultant force magnitude is approximately:
2 × 50 × sin(45°) = 70.7 N
This does not mean that a correctly configured tension display should show 70.7 N.
The controller may be designed to calculate the web tension, which remains 50 N in this example.
What If the Wrap Angle Changes?
The resultant force changes even if the web tension remains constant.
This is why the calibration cord should follow the same path as the actual paper web.
What About Two Load Cells?
When a measuring roller is supported by two sensors, the forces are distributed between those supports.
Under symmetric loading, the supports may share the load approximately equally.
In practice, load distribution depends on geometry, sensor mounting, and the location of the applied force.
This is another reason to use the approved calibration procedure instead of independently guessing the force acting on each sensor.
11. Step 6: Verify the Calibration at Additional Loads
After completing the zero and span adjustments, the measurement should be checked.
A practical verification method is to apply other known loads within the permitted calibration range.
For example, the manufacturer may specify several verification points across the normal operating range.
The precise points depend on the instrument and quality requirements.
Example Verification Record
The following table is an illustrative format, not actual JOTA test data.
| Reference Mass | Approximate Reference Force | Measured Tension | Result |
|---|---|---|---|
| 1 kg | 9.81 N | Record reading | Check against tolerance |
| 2 kg | 19.62 N | Record reading | Check against tolerance |
| 3 kg | 29.43 N | Record reading | Check against tolerance |
| 4 kg | 39.24 N | Record reading | Check against tolerance |
| 5 kg | 49.05 N | Record reading | Check against tolerance |
The reference force values assume approximately 9.81 m/s² gravitational acceleration.
The measured values must come from the actual instrument.
Check Loading and Unloading
Where permitted by the calibration procedure, check the system as the reference load increases and then decreases.
Differences between the readings may indicate hysteresis or another measurement issue.
Calculate the Error
A simple absolute indication error is:
Error = Displayed Value − Reference Value
For a percentage of full-scale calculation:
Error (%FS) = Error ÷ Full-Scale Value × 100%
The reference and displayed values must use consistent units and represent the same physical quantity.
What Is an Acceptable Calibration Error?
There is no universal tolerance that applies to every industrial web tension sensor.
The allowable error depends on the load cell, amplifier, controller, mechanical arrangement, calibration procedure, and required measurement performance.
The factory should use the equipment manufacturer’s published specifications or its own justified quality acceptance criteria.
A tolerance such as ±0.1% FS or ±0.5% FS should not be assumed without supporting documentation.
12. Common Mistakes During Weight Calibration
Several setup errors can produce misleading results.
| Problem | Why It Matters | Recommended Action |
|---|---|---|
| Calibration cord follows the wrong path | Changes the wrap geometry | Reproduce the approved web path |
| Weight is not free-hanging | Actual applied tension becomes uncertain | Use a suitable clear suspension path |
| Cord passes over a braked roller | Friction changes the cord tension | Use the specified free-turning idlers |
| Zero is set with web tension present | Creates an incorrect offset | Remove or relax the web before zeroing |
| Wrong unit entered | Applies incorrect calibration scaling | Confirm kg, kgf or N requirements |
| Weight is too large | May overload the sensor or structure | Observe rated load limits |
| Sensor is mechanically constrained | Adds unwanted forces | Inspect mounting and roller movement |
| Readings fluctuate continuously | May indicate electrical or mechanical trouble | Diagnose before recalibration |
| Calibration parameters are not saved | New settings may be lost | Verify storage and restart behaviour |
| Calibration is not verified | Errors may remain undetected | Test additional reference loads |
A stable tension display does not necessarily indicate accurate calibration.
Similarly, an unstable display may be caused by problems that electronic adjustment cannot correct.
13. What Should You Do If Calibration Fails?
Suppose a 5 kg test weight has been installed correctly, but the tension indicator cannot produce the expected reading.
Before changing additional parameters, review the complete measurement chain.
Check the Sensor Capacity
Confirm that the test load and resulting forces are within the rated operating limits.
An unsuitable sensor rating may affect measurement resolution or risk overload.
Check the Electrical Connections
Inspect the load-cell wiring and signal connections.
Depending on the sensor type, check the excitation supply and signal output using the manufacturer-approved diagnostic method.
Check Sensor Orientation
A load cell mounted in the wrong direction may not measure the intended force correctly.
Check the Controller Configuration
Verify the selected sensor inputs, amplifier parameters, tension units, and any configured wrap-angle compensation.
Inspect Mechanical Interference
Check whether roller movement or bearing operation is restricted.
Unexpected contact with neighbouring machine components can alter the load measurement.
Consider Sensor Damage
If the output remains abnormal after the installation and controller have been checked, the load cell or electronics may require specialist testing or replacement.
Repeatedly adjusting the span is not an appropriate solution for a damaged measuring system.
14. How Often Should a Web Tension Sensor Be Calibrated?
Calibration frequency depends on the application and the manufacturer’s recommendations.
A factory may establish a verification schedule based on operating conditions, measurement criticality, previous results, and maintenance history.
Additional checks may be appropriate after:
- Replacing a load cell or measuring roller
- Changing the web path or wrap geometry
- Repairing the mounting structure
- Replacing the tension amplifier or controller
- Identifying unexpected tension readings
- Performing relevant major maintenance
Should the Sensor Be Calibrated Every Month?
Not necessarily.
There is no universal monthly interval for every tension measurement system.
Some installations may require more frequent checks, while others remain stable over longer periods.
The appropriate schedule should be based on the equipment documentation and the factory’s quality requirements.
Keep Calibration Records
A useful record includes the sensor identification, calibration date, reference weight, instrument settings, verification results, technician, and next review date.
This makes it easier to identify changes over time.
15. Why Accurate Tension Measurement Matters for Slitting and Rewinding
A slitter rewinder must maintain suitable material tension as the web moves from the unwinding section through the converting process.
Different operating zones may use different tension-control arrangements.
Some machines rely on load-cell feedback.
Others use dancer systems, torque control, or combinations of these technologies.
During Unwinding
The jumbo paper roll gradually decreases in diameter.
The unwind control system must regulate material delivery while accounting for the changing roll characteristics.
If the tension measurement is inaccurate, the control system may respond to an incorrect value.
During Slitting
The paper must remain sufficiently stable while passing through the cutting section.
Unstable web tension may contribute to wrinkles or irregular material movement.
However, cutting defects may also result from knife settings, roller alignment, and other mechanical causes.
During Rewinding
The finished paper rolls must develop suitable winding firmness.
Where a load-cell feedback loop is part of the winding system, measurement accuracy can influence the controller’s behaviour.
But winding torque, roll diameter, pressure, and machine configuration also affect the finished roll structure.
Calibration ensures that the tension measurement is trustworthy. It does not automatically guarantee correct winding quality.
16. Web Tension Sensor Calibration on JOTA Machinery Equipment
At JOTA Machinery, we manufacture roll-to-roll converting equipment for thermal paper, labelstock, kraft paper, and other suitable materials.
Depending on the machine configuration, tension measurement and control can involve load cells, tension amplifiers, PLC control, and other components.
When a machine uses a load-cell measuring roller, correct zero and span calibration help establish reliable tension feedback.
What Operators Should Confirm
Before calibrating a JOTA machine, identify the installed load-cell model and the corresponding controller or amplifier.
The sensor rating, wiring configuration, web path, and operating units must match the equipment.
Use the Actual Machine Manual
The calibration sequence should follow the supplied electrical and operating documentation.
Different controller models may use different menu structures or adjustment methods.
A generic calibration procedure cannot replace those instructions.
When Should You Contact Technical Support?
If the displayed tension cannot be zeroed, the readings are unstable, or the reference weight produces an unexpected result, record the relevant information before requesting assistance.
Useful information includes the machine model, sensor identification, controller model, current calibration parameters, test weight, and photographs of the calibration setup.
Our engineering and after-sales teams can use those details to help investigate the problem on applicable JOTA equipment.
Conclusion: Use a Known Weight and Reproduce the Real Web Path
Calibrating a web tension sensor with a known test weight is a practical method for checking the accuracy of a slitter rewinder’s tension measurement system.
However, the procedure depends on the sensor installation.
For a conventional measuring-roller load-cell arrangement, the calibration cord should follow the normal web path so the roller experiences the correct force geometry.
The process generally involves inspecting the sensor installation, removing normal web tension, performing zero calibration, applying a known reference load, adjusting the calibration span, and verifying the measurement.
The test weight must be appropriate for the sensor rating and calibration procedure.
The suspended load must be handled safely, and the web path must avoid sources of uncontrolled friction.
After calibration, the operator should verify additional measurement points and document the results.
A correctly calibrated tension sensor does not simply display a number. It provides a dependable measurement that the operator and control system can use when managing the material web.
Need Assistance With Web Tension Control on a Slitter Rewinder?
JOTA Machinery manufactures slitting and rewinding equipment for thermal paper and other roll-to-roll converting applications.
If your machine is experiencing unstable tension readings, incorrect zero values, or inconsistent tension feedback, provide the machine model, load-cell details, tension controller model, and relevant operating conditions.
Our engineering team can review the information and help identify the appropriate troubleshooting and calibration procedure for your installed equipment.